Table 1. Cab Troubleshooting Without Codes. - Continued.
Table 1. Cab Troubleshooting Without Codes. - Continued.

Field Maintenance Manual 1 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  717    718    719    720    721  722  723    724    725    726    727  
img
. . . . . . . . .
TM 5-2410-240-23-1
0021
Table 1. Cab Troubleshooting Without Codes. - Continued.
0021
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
6. Front Flood Lamp(s) Will Not
4. Using digital multimeter, mea-
Resistance Less Than 5.0 Ohms
Work - Continued
sure resistance (WP 0283)
- Install LH (inner) front flood lamp
between HL-C22 terminal 2
#2, LH (outer) front flood lamp #1,
(WP 0018, Figure 180) and
RH (inner) front flood lamp #2, and
ground.
RH (outer) front flood lamp #1 on
machine (WP 0256).
Connect HL-C1 (WP 0018, Figure
175) on C-C101 (WP 0018, Figure
46) (WP 0229).
Connect C-C30 (WP 0018, Figure
27) on flood lamp relay #1 (WP
0018, Figure 54).
For D6K Dozer with Ripper, install
ripper operation control handle
(WP 0218). For D6K Dozer with
Winch, install winch operation
control handle (WP 0217).
Install headliner on machine (WP
0219).
Verify proper operation of flood
lamps (TM 5-2410-240-10).
Resistance 5.0 Ohms or Greater
- Replace upper cab wiring
harness (WP 0229).
Install LH (inner) front flood lamp
#2, LH (outer) front flood lamp #1,
RH (inner) front flood lamp #2, and
RH (outer) front flood lamp #1 on
machine (WP 0256).
Connect C-C30 (WP 0018, Figure
27) on flood lamp relay #1 (WP
0018, Figure 54).
For D6K Dozer with Ripper, install
ripper operation control handle
(WP 0218). For D6K Dozer with
Winch, install winch operation
control handle (WP 0217).
Verify proper operation of flood
lamps (TM 5-2410-240-10).