TM 5-2410-240-23-1
0021
Table 1. Cab Troubleshooting Without Codes. - Continued.
0021
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
6. Front Flood Lamp(s) Will Not
Work - Continued
for continuity (WP 0283)
Continuity - Replace fuse block
between FP-C5 terminal 8 and
and circuit breaker panel wiring
all other terminals in FP-C5
harness (WP 0201).
Install new front flood lamp fuse on
fuse block.
Verify proper operation of flood
lamps (TM 5-2410-240-10).
for continuity (WP 0283)
Step 18.
between FP-C5 terminal 8
Continuity - Replace fuse block
and circuit breaker panel wiring
ground.
harness (WP 0201).
Install new front flood lamp fuse on
fuse block.
Verify proper operation of flood
lamps (TM 5-2410-240-10).
Test Step 18. Test 118-RD Fused
Front Flood Lamp Circuit for
Short to Other Circuits in Lower
Cab Wiring Harness.
1. For D6K Dozer with Ripper,
remove ripper operation con-
trol handle (WP 0218) and
position aside. For D6K Dozer
with Winch, remove winch
operation control handle (WP
0217) and position aside.
2. Disconnect harness connec-
27) from flood lamp relay #1
for continuity (WP 0283)
Continuity - Replace lower cab
between C-C40 terminal 8 and
wiring harness (WP 0228).
all other terminals in C-C40
Install new front flood lamp fuse on
fuse block.
Install fuse panel front cover on
machine (TM 5-2410-240-10).
Verify proper operation of flood
lamps (TM 5-2410-240-10).
0021-120