Table 1. Cab Troubleshooting Without Codes. - Continued.
Table 1. Cab Troubleshooting Without Codes. - Continued.

Field Maintenance Manual 1 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  720    721    722    723    724  725  726    727    728    729    730  
img
. . .
TM 5-2410-240-23-1
0021
Table 1. Cab Troubleshooting Without Codes. - Continued.
0021
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
6. Front Flood Lamp(s) Will Not
Work - Continued
Figure 42. Flood Lamp and Bulb Connector Terminals.
0021
Test Step 17. Test 118-RD Fused
Front Flood Lamp Circuit for
Short to Other Circuits in Fuse
Block and Circuit Breaker Panel
Wiring Harness.
1. Remove fuse panel side cover
from machine (TM 5-2410-
240-10).
N OT E
Note location of tiedown straps to aid installation.
2. Remove three tiedown straps
and disconnect harness con-
nector FP-C5 (WP 0018, Fig-
ure 170) from harness
connector C-C40 (WP 0018,
Figure 30) (WP 0201). Discard
tiedown straps.
0021-119