TM 5-2410-240-23-1
0021
Table 1. Cab Troubleshooting Without Codes. - Continued.
0021
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
6. Front Flood Lamp(s) Will Not
Work - Continued
27) on flood lamp relay #1 (WP
For D6K Dozer with Ripper, install
ripper operation control handle
(WP 0218). For D6K Dozer with
Winch, install winch operation
control handle (WP 0217).
30) (WP 0201). Install three new
tiedown straps on fuse block and
circuit breaker panel wiring
harness and machine as noted
during removal.
Install fuse panel side cover on
machine (TM 5-2410-240-10).
Install new front flood lamp fuse on
fuse block.
Install fuse panel front cover on
machine (TM 5-2410-240-10).
Verify proper operation of flood
lamps (TM 5-2410-240-10).
Figure 43. Flood Lamp and Bulb Connector Terminals.