Table 1. Cab Troubleshooting Without Codes. - Continued.
Figure 49. Rear Flood Lamp Fuse Top Terminal.

Field Maintenance Manual 1 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  738    739    740    741    742  743  744    745    746    747    748  
img
.
TM 5-2410-240-23-1
0021
Table 1. Cab Troubleshooting Without Codes. - Continued.
0021
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
7. Rear Flood Lamp(s) Will Not
Test Step 5. Test 177-RD Main
Work - Continued
Breaker Output Circuit for Open
Inside Fuse Block.
1. Turn flood lamp switch to OFF
position (TM 5-2410-240-10).
2. Turn battery disconnect switch
to OFF position (TM 5-2410-
240-10).
3. Remove fuse panel front cover
from machine (TM 5-2410-
240-10).
4. Turn battery disconnect switch
to ON position (TM 5-2410-
240-10).
5. Using a digital multimeter,
Voltage Within 18 to 26 Volts -
measure for voltage (WP
Proceed to Test Step 6.
0283) between rear flood lamp
Voltage Not Within 18 to 26
fuse bottom terminal C5 (Fig-
Volts - Replace fuse block and
ure 48) and ground.
circuit breaker panel (WP 0201).
Verify proper operation of flood
lamps (TM 5-2410-240-10).
Figure 48. Rear Flood Lamp Fuse Bottom Terminal.