Figure 48. Rear Flood Lamp Fuse Bottom Terminal.
Table 1. Cab Troubleshooting Without Codes. - Continued.

Field Maintenance Manual 1 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  739    740    741    742    743  744  745    746    747    748    749  
img
. . . .
TM 5-2410-240-23-1
0021
Table 1. Cab Troubleshooting Without Codes. - Continued.
0021
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
7. Rear Flood Lamp(s) Will Not
Test Step 6. Test for Open Rear
Work - Continued
Flood Lamp Fuse.
Using a digital multimeter,
Voltage Within 18 to 26 Volts -
measure for voltage (WP 0283)
Proceed to Test Step 7.
between rear flood lamp fuse top
Voltage Not Within 18 to 26
terminal C4 (Figure 49) and
Volts - Turn battery disconnect
ground.
switch to OFF position (TM 5-
2410-240-10).
Remove rear flood lamp fuse from
fuse block and discard fuse.
Proceed to Test Step 15.
Figure 49. Rear Flood Lamp Fuse Top Terminal.
0021
Test Step 7. Test for Voltage to
Flood Lamp Relay.
1. Turn battery disconnect switch
to OFF position (TM 5-2410-
240-10).
2. For D6K Dozer with Ripper,
remove ripper operation con-
trol handle (WP 0218) and
position aside. For D6K Dozer
with Winch, remove winch
operation control handle (WP
0217) and position aside.
3. Disconnect harness connec-
tor C-C31 (WP 0018, Figure
28) from flood lamp relay (WP
0018, Figure 55).