• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Table 2. Cab Troubleshooting With Codes. - Continued.
Table 2. Cab Troubleshooting With Codes. - Continued.

Field Maintenance Manual 1 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  805    806    807    808    809  810  811    812    813    814    815  
img
. . . . . . . . . . .
TM 5-2410-240-23-1
0021
Table 2. Cab Troubleshooting With Codes. - Continued.
0021
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
1699-04 Joystick Position Sensor
6. Using digital multimeter, mea-
Voltage Less Than Specified
(Forward/Reverse) Voltage Below
sure for voltage (WP 0283)
Range - Proceed to step 7.
Normal - Continued
between harness connector
Voltage Within Specified Range
CA-C5 (WP 0018, Figure 71)
- Replace left joystick control (WP
terminal 2 and 3.
0239). Ensure all harness connec-
There should be approximately
tors are reconnected. Verify proper
5 volts 0.5 volts.
operation of machine (TM 5-2410-
240-10).
7. Turn ignition switch and bat-
tery disconnect switch to the
OFF position (TM 5-2410-240-
10).
8. Disconnect harness connec-
tor CA-C1 (WP 0018, Figure
69) from harness connector C-
C24 (WP 0018, Figure 26).
9. Using digital multimeter, test
No Continuity - Replace seat har-
for continuity (WP 0283)
ness (WP 0236). Ensure all har-
between harness connector
ness connectors are reconnected.
CA-C1 (WP 0018, Figure 69)
Verify proper operation of machine
terminal 2 and harness con-
(TM 5-2410-240-10).
nector CA-C5 (WP 0018, Fig-
Continuity - Proceed to step 10.
ure 71) terminal 1.
10. Using digital multimeter, test
No Continuity - Replace seat har-
for continuity (WP 0283)
ness (WP 0236). Ensure all har-
between harness connector
ness connectors are reconnected.
CA-C1 (WP 0018, Figure 69)
Verify proper operation of machine
terminal 9 and harness con-
(TM 5-2410-240-10).
nector CA-C5 (WP 0018, Fig-
Continuity - Proceed to step 11.
ure 71) terminal 2.
11. Using digital multimeter, test
No Continuity - Replace seat har-
for continuity (WP 0283)
ness (WP 0236). Ensure all har-
between harness connector
ness connectors are reconnected.
CA-C1 (WP 0018, Figure 69)
Verify proper operation of machine
terminal 6 and harness con-
(TM 5-2410-240-10).
nector CA-C5 (WP 0018, Fig-
Continuity - Proceed to step 12.
ure 71) terminal 3.
12. Using digital multimeter, test
No Continuity - Proceed to
for continuity (WP 0283)
step 13.
between harness connector
Continuity - Replace seat harness
CA-C1 (WP 0018, Figure 69)
(WP 0236). Ensure all harness
terminal 6 and all other termi-
connectors are reconnected. Verify
nals in harness connector CA-
proper operation of machine (TM
C1 (WP 0018, Figure 69).
5-2410-240-10).
0021-204