Table 2. Cab Troubleshooting With Codes. - Continued.
Table 2. Cab Troubleshooting With Codes. - Continued.

Field Maintenance Manual 1 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  809    810    811    812    813  814  815    816    817    818    819  
img
. . . . . . . . . . . . . .
TM 5-2410-240-23-1
0021
Table 2. Cab Troubleshooting With Codes. - Continued.
0021
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
1699-08 Joystick Position Sensor
11. Using digital multimeter, test
No Continuity - Replace seat har-
(Forward/Reverse) Abnormal Fre-
for continuity (WP 0283)
ness (WP 0236). Ensure all har-
quency, Pulse Width, or Period
between harness connector
ness connectors are reconnected.
Continued
CA-C1 (WP 0018, Figure 69)
Verify proper operation of machine
terminal 6 and harness con-
(TM 5-2410-240-10).
nector CA-C5 (WP 0018, Fig-
Continuity - Proceed to step 12.
ure 71) terminal 3.
12. Using digital multimeter, test
No Continuity - Proceed to
for continuity (WP 0283)
step 13.
between harness connector
Continuity - Replace seat harness
CA-C1 (WP 0018, Figure 69)
(WP 0236). Ensure all harness
terminal 6 and all other termi-
connectors are reconnected. Verify
nals in harness connector CA-
proper operation of machine (TM
C1 (WP 0018, Figure 69).
5-2410-240-10).
13. Disconnect harness connec-
tor C-C12 (WP 0018, Figure
22) from PL-C1 (WP 0018,
Figure 214).
14. Using digital multimeter, test
No Continuity - Replace lower
for continuity (WP 0283)
cab harness (WP 0228). Ensure all
between harness connector
harness connectors are recon-
C-C12 (WP 0018, Figure 22)
nected. Verify proper operation of
terminal 45 and harness con-
machine (TM 5-2410-240-10).
nector C-C24 (WP 0018, Fig-
Continuity - Proceed to step 15.
ure 26) terminal 2.
15. Using digital multimeter, test
No Continuity - Replace lower
for continuity (WP 0283)
cab harness (WP 0228). Ensure all
between harness connector
harness connectors are recon-
C-C12 (WP 0018, Figure 22)
nected. Verify proper operation of
terminal 44 and harness con-
machine (TM 5-2410-240-10).
nector C-C24 (WP 0018, Fig-
Continuity - Proceed to step 16.
ure 26) terminal 9.
16. Using digital multimeter, test
No Continuity - Replace lower
for continuity (WP 0283)
cab harness (WP 0228). Ensure all
between harness connector
harness connectors are recon-
C-C12 (WP 0018, Figure 22)
nected. Verify proper operation of
terminal 42 and harness con-
machine (TM 5-2410-240-10).
nector C-C24 (WP 0018, Fig-
Continuity - Proceed to step 17.
ure 26) terminal 6.
17. Using digital multimeter, test
No Continuity - Proceed to
for continuity (WP 0283)
step 18.
between harness connector
Continuity - Replace lower cab
C-C12 (WP 0018, Figure 22)
harness (WP 0228). Ensure all
terminal 42 and all other termi-
harness connectors are recon-
nals in harness connector C-
nected. Verify proper operation of
C12 (WP 0018, Figure 22).
machine (TM 5-2410-240-10).
0021-208