Table 2. Cab Troubleshooting With Codes. - Continued.
0021
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
1699-08 Joystick Position Sensor
18. Disconnect harness connec-
(Forward/Reverse) Abnormal Fre-
tor PL-C4 (WP 0018, Figure
quency, Pulse Width, or Period
217) from equipment ECM J1.
Continued
19. Disconnect harness connec-
tor PL-C5 (WP 0018, Figure
218) from equipment ECM J2.
20. Using digital multimeter, test
No Continuity - Replace platform
for continuity (WP 0283)
wiring harness (WP 0150, WP
between harness connector
0155). Ensure all harness connec-
PL-C4 (WP 0018, Figure 217)
tors are reconnected. Verify proper
terminal 69 and harness con-
operation of machine (TM 5-2410-
nector PL-C1 (WP 0018, Fig-
240-10).
ure 214) terminal 45.
Continuity - Proceed to step 21.
21. Using digital multimeter, test
No Continuity - Replace platform
for continuity (WP 0283)
wiring harness (WP 0150,
between harness connector
WP 0155). Ensure all harness con-
PL-C4 (WP 0018, Figure 217)
nectors are reconnected. Verify
terminal 56 and harness con-
proper operation of machine (TM
nector PL-C1 (WP 0018, Fig-
5-2410-240-10).
ure 214) terminal 44.
Continuity - Proceed to step 22.
22. Using digital multimeter, test
No Continuity - Replace platform
for continuity (WP 0283)
wiring harness (WP 0150,
between harness connector
WP 0155). Ensure all harness con-
PL-C5 (WP 0018, Figure 218)
nectors are reconnected. Verify
terminal 26 and harness con-
proper operation of machine (TM
nector PL-C1 (WP 0018,
5-2410-240-10).
Figure 214) terminal 42.
Continuity - Proceed to step 23.
23. Using digital multimeter, test
No Continuity - Replace machine
for continuity (WP 0283)
ECM (WP 0147, WP 0149).
between harness connector
Ensure all harness connectors are
PL-C5 (WP 0018, Figure 218)
reconnected. Verify proper opera-
terminal 26 and all other termi-
tion of machine (TM 5-2410-240-
nals in harness connector PL-
10).
C5 (WP 0018, Figure 218).
Continuity - Replace platform har-
ness (WP 0150, WP 0155).
Ensure all harness connectors are
reconnected. Verify proper opera-
tion of machine (TM 5-2410-240-
10).
1699-13 Joystick Position Sensor
Joystick forward/reverse position
Perform Operator Control Calibra-
(Forward/Reverse) Out of Calibration sensor requires calibration.
tions (Hystat) (WP 0033). If diag-
nostic code returns, replace
machine ECM (WP 0147,
WP 0149).
0021-209