  883    884    885    886    887  888  889    890    891    892    893  
img
. . . . . . . . . . . . . .
TM 5-2410-240-23-1
0021
Table 2. Cab Troubleshooting With Codes. - Continued.
0021
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
2532-04 Operator Gear Ratio Set/
10. Using digital multimeter, test
No Continuity - Proceed to
Recall Switch Position Voltage
for continuity (WP 0283)
step 11.
Below Normal - Continued
between harness connector
Continuity - Replace seat harness
CA-C1 (WP 0018, Figure 69)
(WP 0236). Ensure all harness
terminal 5 and all other termi-
connectors are reconnected. Verify
nals in harness connector CA-
proper operation of machine (TM
C1 (WP 0018, Figure 69).
5-2410-240-10).
11. Using digital multimeter, test
No Continuity - Proceed to
for continuity (WP 0283)
step 12.
between harness connector
Continuity - Replace seat harness
CA-C2 (WP 0018, Figure 70)
(WP 0236). Ensure all harness
terminal 1 and all other termi-
connectors are reconnected. Verify
nals in harness connector CA-
proper operation of machine (TM
C2 (WP 0018, Figure 70).
5-2410-240-10).
12. Disconnect harness connec-
tor C-C12 (WP 0018, Figure
22) from PL-C1 (WP 0018,
Figure 214).
13. Using digital multimeter, test
No Continuity - Replace lower
for continuity (WP 0283)
cab harness (WP 0228). Ensure all
between harness connector
harness connectors are recon-
C-C12 (WP 0018, Figure 22)
nected. Verify proper operation of
terminal 41 and harness con-
machine (TM 5-2410-240-10).
nector C-C24 (WP 0018, Fig-
Continuity - Proceed to step 14.
ure 26) terminal 5.
14. Using digital multimeter, test
No Continuity - Replace lower
for continuity (WP 0283)
cab harness (WP 0228). Ensure all
between harness connector
harness connectors are recon-
C-C12 (WP 0018, Figure 22)
nected. Verify proper operation of
terminal 44 and harness con-
machine (TM 5-2410-240-10).
nector C-C24 (WP 0018, Fig-
Continuity - Proceed to step 15.
ure 26) terminal 9.
15. Using digital multimeter, test
No Continuity - Replace lower
for continuity (WP 0283)
cab harness (WP 0228). Ensure all
between harness connector
harness connectors are recon-
C-C12 (WP 0018, Figure 22)
nected. Verify proper operation of
terminal 39 and harness con-
machine (TM 5-2410-240-10).
nector C-C23 (WP 0018, Fig-
Continuity - Proceed to step 16.
ure 25) terminal 1.
16. Using digital multimeter, test
No Continuity - Proceed to
for continuity (WP 0283)
step 17.
between harness connector
Continuity - Replace lower cab
C-C12 (WP 0018, Figure 22)
harness (WP 0228). Ensure all
terminal 39 and all other termi-
harness connectors are recon-
nals in harness connector C-
nected. Verify proper operation of
C12 (WP 0018, Figure 22).
machine (TM 5-2410-240-10).
0021-282