Table 2. Cab Troubleshooting With Codes. - Continued.
0021
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
2532-04 Operator Gear Ratio Set/
17. Using digital multimeter, test
No Continuity - Proceed to
Recall Switch Position Voltage
for continuity (WP 0283)
step 18.
Below Normal - Continued
between harness connector
Continuity - Replace lower cab
C-C12 (WP 0018, Figure 22)
harness (WP 0228). Ensure all
terminal 41 and all other termi-
harness connectors are recon-
nals in harness connector C-
nected. Verify proper operation of
C12 (WP 0018, Figure 22).
machine (TM 5-2410-240-10).
18. Disconnect harness connec-
tor PL-C4 (WP 0018, Figure
217) from equipment ECM J1.
19. Using digital multimeter, test
No Continuity - Replace platform
for continuity (WP 0283)
wiring harness (WP 0150,
between harness connector
WP 0155). Ensure all harness con-
PL-C4 (WP 0018, Figure 217)
nectors are reconnected. Verify
terminal 41 and harness con-
proper operation of machine (TM
nector PL-C1 (WP 0018, Fig-
5-2410-240-10).
ure 214) terminal 39.
Continuity - Proceed to step 20.
20. Using digital multimeter, test
No Continuity - Replace platform
for continuity (WP 0283)
wiring harness (WP 0150,
between harness connector
WP 0155). Ensure all harness con-
PL-C4 (WP 0018, Figure 217)
nectors are reconnected. Verify
terminal 56 and harness con-
proper operation of machine (TM
nector PL-C1 (WP 0018, Fig-
5-2410-240-10).
ure 214) terminal 44.
Continuity - Proceed to step 21.
21. Using digital multimeter, test
No Continuity - Replace platform
for continuity (WP 0283)
wiring harness (WP 0150,
between harness connector
WP 0155). Ensure all harness con-
PL-C4 (WP 0018, Figure 217)
nectors are reconnected. Verify
terminal 42 and harness con-
proper operation of machine (TM
nector PL-C1 (WP 0018, Fig-
5-2410-240-10).
ure 214) terminal 41.
Continuity - Proceed to step 22.
22. Using digital multimeter, test
No Continuity - Proceed to
for continuity (WP 0283)
step 23.
between harness connector
Continuity - Replace platform wir-
PL-C4 (WP 0018, Figure 217)
ing harness (WP 0150, WP 0155).
terminal 42 and all other termi-
Ensure all harness connectors are
nals in harness connector PL-
reconnected. Verify proper opera-
C4 (WP 0018, Figure 217).
tion of machine (TM 5-2410-240-
10).