TM 5-2410-240-23-1
0021
Table 2. Cab Troubleshooting With Codes. - Continued.
0021
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
2661-03 Cab Air Temperature Con-
trol Voltage Above Normal - Contin-
for continuity (WP 0283)
harness (WP 0150, WP 0155).
ued
Ensure all harness connectors are
Figure 214) harness connec-
reconnected. Verify proper opera-
tor terminal 44 and PL-C4 (WP
tion of machine (TM 5-2410-240-
0018, Figure 217) equipment
10).
ECM J1 terminal 56.
trol panel (WP 0212). Ensure all
harness connectors are recon-
nected. Verify proper operation of
machine (TM 5-2410-240-10).
If diagnostic code returns, replace
machine ECM (WP 0147,
WP 0149).
N OT E
2661-04 Cab Air Temperature Con-
trol Voltage Below Normal
Always inspect harness connectors that are involved in circuit.
Poor connections can often be the cause of an electrical circuit
problem. Verify that all connections in circuit are clean and
secure, and connections are in good condition. If a problem with
connection is found, correct problem and verify diagnostic code
is active before performing this procedure.
Tag wiring harnesses to aid installation.
Perform this test only if condition is active.
1. Turn ignition switch and bat-
tery disconnect switch to OFF
position (TM 5-2410-240-10).
2. Disconnect harness connec-
32) from HVAC control panel.
3. Disconnect harness connec-
Figure 214).
for continuity (WP 0283)
cab harness (WP 0228). Ensure all
between harness connector
harness connectors are recon-
nected. Verify proper operation of
terminal 11 and harness con-
machine (TM 5-2410-240-10).
ure 22) terminal 38.