Table 2. Cab Troubleshooting With Codes. - Continued.
Table 2. Cab Troubleshooting With Codes. - Continued.

Field Maintenance Manual 1 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  893    894    895    896    897  898  899    900    901    902    903  
img
. . . . . . .
TM 5-2410-240-23-1
0021
Table 2. Cab Troubleshooting With Codes. - Continued.
0021
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
2663-03 Cab Ventilation Duct Tem-
16. Using digital multimeter, test
No Continuity - Replace platform
perature Sensor Voltage Above Nor-
for continuity (WP 0283)
wiring harness (WP 0150,
mal - Continued
between harness connector
WP 0155). Ensure all harness con-
PL-C3 (WP 0018, Figure 216)
nectors are reconnected. Verify
terminal 26 and harness con-
proper operation of machine (TM
nector PL-C4 (WP 0018, Fig-
5-2410-240-10).
ure 217) terminal 21.
Continuity - Proceed to step 17.
17. Using digital multimeter, test
No Continuity - Replace machine
for continuity (WP 0283)
ECM (WP 0147, WP 0149).
between harness connector
Ensure all harness connectors are
PL-C4 (WP 0018, Figure 217)
reconnected. Verify proper opera-
terminal 53 and all other termi-
tion of machine (TM 5-2410-240-
nals in harness connector PL-
10).
C4 (WP 0018, Figure 217).
Continuity - Replace fuse panel
wiring harness (WP 0201). Ensure
all harness connectors are recon-
nected. Verify proper operation of
machine (TM 5-2410-240-10).
N OT E
2663-04 Cab Ventilation Duct Tem-
perature Sensor Voltage Below Nor-
Always inspect harness connectors that are involved in circuit.
mal
Poor connections can often be the cause of an electrical circuit
problem. Verify that all connections in circuit are clean and
secure, and connections are in good condition. If a problem with
connection is found, correct problem and verify diagnostic code
is active before performing this procedure.
 Tag wiring harnesses to aid installation.
 Perform this test only if condition is active.
1. Turn ignition switch and bat-
tery disconnect switch to OFF
position (TM 5-2410-240-10).
2. Disconnect harness connec-
tor C-C57 (WP 0018, Figure
40) from A/C recirculation tem-
perature sensor (WP 0018,
Figure 47).
3. Turn battery disconnect switch
and ignition switch to ON posi-
tion (TM 5-2410-240-10).
0021-292