Table 2. Cab Troubleshooting With Codes. - Continued.
Table 2. Cab Troubleshooting With Codes. - Continued.

Field Maintenance Manual 1 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  897    898    899    900    901  902  903    904    905    906    907  
img
. . . . . . . . .
TM 5-2410-240-23-1
0021
Table 2. Cab Troubleshooting With Codes. - Continued.
0021
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
N OT E
2671-06 Air Conditioner Compres-
sor Clutch Solenoid Current Above
Always inspect harness connectors that are involved in e circuit.
Normal
Poor connections can often be the cause of an electrical circuit
problem. Verify that all connections in circuit are clean and
secure, and connections are in good condition. If a problem with
connection is found, correct problem and verify diagnostic code
is active before performing this procedure.
Tag wiring harnesses to aid installation.
Perform this test only if condition is active.
1. Disconnect harness connec-
tor PL-C29 (WP 0018, Figure
231) from A/C clutch solenoid
relay (WP 0018, Figure 239).
2. Using digital multimeter, mea-
Resistance Within Specified
sure resistance (WP 0283) of
Range - Proceed to step 3.
relay coil between A/C clutch
Resistance If Not Within Speci-
solenoid relay (WP 0018, Fig-
fied Range - Replace A/C clutch
ure 239) terminal 5 (A/C relay
solenoid relay (WP 0150,
86) and terminal 2 (A/C relay
WP 0155). Ensure all harness con-
85).
nectors are reconnected. Verify
Resistance should be between
proper operation of machine (TM
288 and 396 ohms.
5-2410-240-10).
3. Disconnect harness connec-
tor PL-C5 (WP 0018, Figure
218) from equipment ECM J2.
4. Using digital multimeter, test
No Continuity - Replace platform
for continuity (WP 0283)
wiring harness (WP 0150,
between harness connector
WP 0155). Ensure all harness con-
PL-C5 (WP 0018, Figure 218)
nectors are reconnected. Verify
terminal 12 and harness con-
proper operation of machine
nector PL-C29 (WP 0018, Fig-
(TM 5-2410-240-10).
ure 231) terminal 5.
Continuity - Proceed to step 5.
5. Using digital multimeter, test
No Continuity - Replace machine
for continuity (WP 0283)
ECM (WP 0147, WP 0149).
between harness connector
Ensure all harness connectors are
PL-C5 (WP 0018, Figure 218)
reconnected. Verify proper opera-
terminal 12 and all other termi-
tion of machine (TM 5-2410-240-
nals in harness connector PL-
10).
C5 (WP 0018, Figure 218).
Continuity - Replace fuse panel
harness (WP 0201). Ensure all
harness connectors are recon-
nected. Verify proper operation of
machine (TM 5-2410-240-10).
0021-296