• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Table 2. Cab Troubleshooting With Codes. - Continued.
Table 2. Cab Troubleshooting With Codes. - Continued.

Field Maintenance Manual 1 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  895    896    897    898    899  900  901    902    903    904    905  
img
. . . . . . . . .
TM 5-2410-240-23-1
0021
Table 2. Cab Troubleshooting With Codes. - Continued.
0021
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
2663-04 Cab Ventilation Duct Tem-
11. Using digital multimeter, test
No Continuity - Proceed to
perature Sensor Voltage Below Nor-
for continuity (WP 0283)
step 12
mal - Continued
between harness connector
Continuity - Replace fuse panel
FP-C3 (WP 0018, Figure 168)
wiring harness (WP 0201). Ensure
terminal 24 and all other termi-
all harness connectors are recon-
nals in harness connector FP-
nected. Verify proper operation of
C3 (WP 0018, Figure 168).
machine (TM 5-2410-240-10).
12. Disconnect harness connec-
tor PL-C4 (WP 0018, Figure
217) from equipment ECM J1.
13. Using digital multimeter, test
No Continuity - Replace platform
for continuity (WP 0283)
wiring harness (WP 0150,
between harness connector
WP 0155). Ensure all harness con-
PL-C3 (WP 0018, Figure 216)
nectors are reconnected. Verify
terminal 24 and harness con-
proper operation of machine (TM
nector PL-C4 (WP 0018, Fig-
5-2410-240-10).
ure 217) terminal 53.
Continuity - Proceed to step 14.
14. Using digital multimeter, test
No Continuity - Replace platform
for continuity (WP 0283)
wiring harness (WP 0150,
between harness connector
WP 0155). Ensure all harness con-
PL-C3 (WP 0018, Figure 216)
nectors are reconnected. Verify
terminal 26 and harness con-
proper operation of machine
nector PL-C4 (WP 0018, Fig-
(TM 5-2410-240-10).
ure 217) terminal 21.
Continuity - Proceed to step 15.
15. Using digital multimeter, test
No Continuity - Replace machine
for continuity (WP 0283)
ECM (WP 0147, WP 0149).
between harness connector
Ensure all harness connectors are
PL-C4 (WP 0018, Figure 217)
reconnected. Verify proper opera-
terminal 53 and all other termi-
tion of machine (TM 5-2410-240-
nals in harness connector PL-
10).
C4 (WP 0018, Figure 217).
Continuity - Replace fuse panel
wiring harness (WP 0201). Ensure
all harness connectors are recon-
nected. Verify proper operation of
machine (TM 5-2410-240-10).
0021-294