Table 2. Cab Troubleshooting With Codes. - Continued.
Table 2. Cab Troubleshooting With Codes. - Continued.

Field Maintenance Manual 1 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  896    897    898    899    900  901  902    903    904    905    906  
img
. . . . . . . . .
TM 5-2410-240-23-1
0021
Table 2. Cab Troubleshooting With Codes. - Continued.
0021
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
N OT E
2671-05 Air Conditioner Compres-
sor Clutch Solenoid Current Below
Always inspect harness connectors that are involved in circuit.
Normal
Poor connections can often be the cause of an electrical circuit
problem. Verify that all connections in circuit are clean and
secure, and connections are in good condition. If a problem with
connection is found, correct problem and verify diagnostic code
is active before performing this procedure.
Tag wiring harnesses to aid installation.
Perform this test only if condition is active.
1. Disconnect harness connec-
tor PL-C29 (WP 0018, Figure
231) from A/C clutch solenoid
relay (WP 0018, Figure 239).
2. Using digital multimeter, mea-
Resistance Within Specified
sure resistance (WP 0283) of
Range - Proceed to step 3.
relay coil between A/C clutch
Resistance Not Within Speci-
solenoid relay (WP 0018, Fig-
fied Range - Replace A/C clutch
ure 239) terminal 5 (A/C relay
solenoid relay (WP 0150, WP
86) and terminal 2 (A/C relay
0155). Ensure all harness connec-
85).
tors are reconnected. Verify proper
Resistance should be between
operation of machine (TM 5-2410-
288 and 396 ohms.
240-10).
3. Disconnect harness connec-
tor PL-C5 (WP 0018, Figure
218) from equipment ECM J2.
4. Using digital multimeter, test
No Continuity - Replace platform
for continuity (WP 0283)
wiring harness (WP 0150, WP
between harness connector
0155). Ensure all harness connec-
PL-C5 (WP 0018, Figure 218)
tors are reconnected. Verify proper
terminal 12 and harness con-
operation of machine (TM 5-2410-
nector PL-C29 (WP 0018, Fig-
240-10).
ure 231) terminal 5.
Continuity - Proceed to step 5.
5. Using digital multimeter, test
No Continuity - Replace machine
for continuity (WP 0283)
ECM (WP 0147, WP 0149).
between harness connector
Ensure all harness connectors are
PL-C5 (WP 0018, Figure 218)
reconnected. Verify proper opera-
terminal 12 and all other termi-
tion of machine (TM 5-2410-240-
nals in harness connector PL-
10).
C5 (WP 0018, Figure 218).
Continuity - Replace fuse panel
wiring harness (WP 0201). Ensure
all harness connectors are recon-
nected. Verify proper operation of
machine (TM 5-2410-240-10).
0021-295