Table 1. Window Wiper and Washer Troubleshooting Procedures - Continued.
Table 1. Window Wiper and Washer Troubleshooting Procedures - Continued.

Field Maintenance Manual 1 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  917    918    919    920    921  922  923    924    925    926    927  
img
. . . . . . . . . . . . . . . .
TM 5-2410-240-23-1
0022
Table 1. Window Wiper and Washer Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. Front Windshield Wiper
5. Disconnect harness connector
Does Not Operate Prop-
CH-C1 (WP 0018, Figure 81) from
erly Continued
harness connector PL-C18 (WP
0018, Figure 226).
6. Using digital multimeter, test for
No Continuity - Proceed to step 7.
continuity (WP 0283) between
Continuity - Replace chassis harness
harness connector CH-C26 (WP
(WP 0153, WP 0154). Ensure all har-
0018, Figure 97) terminal 4 and
ness connectors are reconnected.
cab ground.
Install a new #26 15A fuse (TM 5-
2410-240-10). Verify proper operation
of machine (TM 5-2410-240-10).
7. Using digital multimeter, test for
No Continuity - Proceed to step 8.
continuity (WP 0283) between
Continuity - Replace chassis harness
harness connector CH-C26 (WP
(WP 0153, WP 0154). Ensure all har-
0018, Figure 97) terminal 4 and
ness connectors are reconnected.
all other terminals in connector
Install a new #26 15A fuse (TM 5-
CH-C26 (WP 0018, Figure 97).
2410-240-10). Verify proper operation
of machine (TM 5-2410-240-10).
8. Disconnect harness connector
PL-C1 (WP 0018, Figure 214)
from harness connector C-C12
(WP 0018, Figure 22).
9. Using digital multimeter, test for
No Continuity - Proceed to step 10.
continuity (WP 0283) between
Continuity - Replace platform har-
harness connector PL-C18 (WP
ness (WP 0150, WP 0155). Ensure all
0018, Figure 226) terminal 35 and
harness connectors are reconnected.
cab ground.
Install a new #26 15A fuse (TM 5-
2410-240-10). Verify proper operation
of machine (TM 5-2410-240-10).
10. Using digital multimeter, test for
No Continuity - Proceed to step 11.
continuity (WP 0283) between
Continuity - Replace platform har-
harness connector PL-C18 (WP
ness (WP 0150, WP 0155). Ensure all
0018, Figure 226) terminal 35 and
harness connectors are reconnected.
all other terminals in connector
Install a new #26 15A fuse (TM 5-
PL-C18 (WP 0018, Figure 226).
2410-240-10). Verify proper operation
of machine (TM 5-2410-240-10).
11. Disconnect front windshield wiper
switch harness connector C-C5
(WP 0018, Figure 17) from front
windshield wiper switch.