Table 1. Window Wiper and Washer Troubleshooting Procedures - Continued.
Table 1. Window Wiper and Washer Troubleshooting Procedures - Continued.

Field Maintenance Manual 1 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  922    923    924    925    926  927  928    929    930    931    932  
img
. . . . . . . . . . . . .
TM 5-2410-240-23-1
0022
Table 1. Window Wiper and Washer Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2. Rear Window Wiper
5. Using digital multimeter, test for
No Continuity - Replace rear wiper
continuity (WP 0283) between
Does Not Operate Prop-
motor (WP 0208). Ensure all harness
rear wiper motor harness connec-
erly Continued
connectors are reconnected. Install a
tor HL-C128 (WP 0018, Figure
new #10 10A fuse (TM 5-2410-240-
184) terminal 3 and cab ground.
10). Verify proper operation of
machine (TM 5-2410-240-10).
Continuity - Proceed to step 6.
6. Disconnect harness connector
HL-C1 (WP 0018, Figure 175)
from harness connector C-C101
(WP 0018, Figure 46).
7. Using digital multimeter, test for
No Continuity - Proceed to step 8.
continuity (WP 0283) between
Continuity - Replace upper cab har-
harness connector HL-C28 (WP
ness (WP 0229). Ensure all harness
0018, Figure 184) terminal 4 and
connectors are reconnected. Install a
cab ground.
new #10 10A fuse (TM 5-2410-240-
10). Verify proper operation of
machine (TM 5-2410-240-10).
8. Using digital multimeter, test for
No Continuity - Proceed to step 9.
continuity (WP 0283) between
Continuity - Replace upper cab
harness connector HL-C28 (WP
harness (WP 0229). Ensure all
0018, Figure 184) terminal 4 and
harness connectors are reconnected.
all other terminals in connector
Install a new #10 10A fuse (TM 5-
HL-C28 (WP 0018, Figure 184).
2410-240-10). Verify proper operation
of machine (TM 5-2410-240-10).
9. Using digital multimeter, test for
No Continuity - Proceed to step 10.
continuity (WP 0283) between
Continuity - Replace upper cab har-
harness connector HL-C28 (WP
ness (WP 0229). Ensure all harness
0018, Figure 184) terminal 2 and
connectors are reconnected. Install a
cab ground.
new #10 10A fuse (TM 5-2410-240-
10). Verify proper operation of
machine (TM 5-2410-240-10).
10. Using digital multimeter, test for
No Continuity - Proceed to step 11.
continuity (WP 0283) between
Continuity - Replace upper cab
harness connector HL-C28 (WP
harness (WP 0229). Ensure all
0018, Figure 184) terminal 2 and
harness connectors are reconnected.
all other terminals in connector
Install a new #10 10A fuse (TM 5-
HL-C28 (WP 0018, Figure 184).
2410-240-10). Verify proper operation
of machine (TM 5-2410-240-10).
0022-17