0497-05 Blade Tilt Right
7. Check for active code 0497-05 or
Code 0497-05 Remains Active - Pro-
Solenoid Current Below Nor-
0497-06 in machine control D6K
ceed to Test Step 3.
mal - Continued
ECM (WP 0016).
Code 0497-05 Becomes Inactive
and 0497-06 Becomes Active - Turn
ignition switch and battery disconnect
switch to OFF position (TM 5-2410-
240-10).
Remove jumper wire from PL-C18 ter-
minal 10 and terminal 17 (WP 0018,
Figure 226).
Replace chassis wiring harness: with
Ripper (WP 0153); with Winch (WP
0154).
Proceed to step 8.
8. Using MSD (WP 0016), select
Code 0497-05 Active - Repeat trou-
machine control D6K ECM and
bleshooting code from the beginning.
verify 0497-05 is not active.
Code 0497-05 Not Active - Trouble-
shooting complete.
Test Step 3. Test M928-BU Blade
Tilt Right Solenoid Circuit for High
Resistance or Open in Platform
Wiring Harness.
1. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-2410-240-10).
2. Remove jumper wire from PL-C18
terminal 10 and terminal 17 (WP
0018, Figure 226).
3. Disconnect platform wiring har-
ness connector PL-C4 (WP 0018,
Figure 217) from ECM J1: with
Ripper (WP 0147); with Winch
(WP 0149).