• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.
Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.

Field Maintenance Manual 1 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  1100    1101    1102    1103    1104  1105  1106    1107    1108    1109    1110  
img
. . . . . . .
TM 5-2410-240-23-1
0023
Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.
0023
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
1933-06 Blade Angle Left
6. Check for active code 1933-05 or
Code 1933-06 Remains Active - Pro-
Solenoid Current Above
1933-06 in machine control D6K
ceed to Test Step 2.
Normal - Continued
ECM (WP 0016).
Code 1933-06 Becomes Inactive
and 1933-05 Becomes Active -
Replace blade angle left solenoid:
with Ripper (WP 0196); with Winch
(WP 0197).
Proceed to step 7.
7. Using MSD (WP 0016), select
Code 1933-06 Active - Repeat trou-
machine control D6K ECM and
bleshooting code from the beginning.
verify 1933-06 is not active.
Code 1933-06 Not Active - Trouble-
shooting complete.
Test Step 2. Test for Shorted Chas-
sis Wiring Harness.
1. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-2410-240-10).
2. Remove right rear access cover
from machine (WP 0191).
3. Disconnect platform wiring har-
ness connector PL-C18 (WP
0018, Figure 226) from chassis
wiring harness connector CH-C1
(WP 0018, Figure 81): with Ripper
(WP 0150); with Winch (WP
0155).
4. Turn battery disconnect switch
and ignition switch to the ON posi-
tion (TM 5-2410-240-10).
Code 1933-06 Remains Active - Pro-
5. Check for active code 1933-05 or
ceed to Test Step 3.
1933-06 in machine control D6K
ECM (WP 0016).
Code 1933-06 Becomes Inactive
and 1933-05 Becomes Active -
Replace chassis wiring harness: with
Ripper (WP 0153); with Winch (WP
0154).
Proceed to step 6.
6. Using MSD (WP 0016), select
Code 1933-06 Active - Repeat trou-
machine control D6K ECM and
bleshooting code from the beginning.
verify 1933-06 is not active.
Code 1933-06 Not Active - Trouble-
shooting complete.
0023-143


Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved.