CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
1933-05 Blade Angle Left
7. Check for active code 1933-05 or
Code 1933-05 Remains Active - Pro-
Solenoid Current Below Nor-
1933-06 in machine control D6K
ceed to Test Step 3.
mal - Continued
ECM (WP 0016).
Code 1933-05 Becomes Inactive
and 1933-06 Becomes Active - Turn
ignition switch and battery disconnect
switch to OFF position (TM 5-2410-
240-10).
Remove jumper wire from PL-C18 ter-
minal 7 and terminal 24 (WP 0018,
Figure 226).
Replace fuel tank and chassis wiring
harness: with Ripper (WP 0153) or
with Winch (WP 0154).
Proceed to step 8.
8. Using MSD (WP 0016), select
Code 1933-05 Active - Repeat trou-
machine control D6K ECM and
bleshooting code from the beginning.
verify 1933-05 is not active.
Code 1933-05 Not Active - Trouble-
shooting complete.
Test Step 3. Test 751-GN Blade
Angle Left Solenoid Circuit for High
Resistance or Open in Platform
Wiring Harness.
1. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-2410-240-10).
2. Remove jumper wire from PL-C18
terminal 7 and terminal 24 (WP
0018, Figure 226).
3. Disconnect platform wiring har-
ness connector PL-C2 (WP 0018,
Figure 215) from equipment ECM
(WP 0148).