TM 5-2410-240-23-1
0023
Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.
0023
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
1934-03 Blade Angle Right
Test Step 3. Test 752-YL Blade
Solenoid Voltage Above Nor- Angle Right Solenoid Circuit for
mal - Continued
Short to Other Voltage Source in
Platform Wiring Harness.
1. Turn battery disconnect switch
and ignition switch to ON position
(TM 5-2410-240-10).
Voltage Greater Than 0.3 Volts -
0283), measure for voltage
Replace platform wiring harness: with
between PL-C2 terminal 48 (WP
Ripper (WP 0150); with Winch (WP
0018, Figure 215) and ground.
0155).
Proceed to step 3.
Voltage 0.3 Volts or Less - Replace
equipment ECM (WP 0148).
Connect platform wiring harness con-
on ECM J2: with Ripper (WP 0147);
with Winch (WP 0149).
Connect platform wiring harness con-
on ECM J1: with Ripper (WP 0147);
with Winch (WP 0149).
Connect platform wiring harness con-
on chassis wiring harness connector
Ripper (WP 0150); with Winch (WP
0155).
Proceed to step 3.
Code 1934-03 Active - Repeat trou-
machine control D6K ECM and
bleshooting code from the beginning.
verify 1934-03 is not active.
Code 1934-03 Not Active - Trouble-
shooting complete.
0023-150