Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.
0023
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
3196-04 Blade Angle Right
7. Using digital multimeter (WP
No Continuity on Test Point - Pro-
Solenoid Voltage Below Nor-
0283), test for continuity between
ceed to Test Step 3.
mal - Continued
CH-C1 terminal 3 (WP 0018, Fig-
Continuity on Test Point - Replace
ure 81) and ground.
chassis wiring harness: with Ripper
(WP 0153); with Winch (WP 0154).
Proceed to step 8.
8. Using MSD (WP 0016), select
Code 3196-04 Active - Repeat trou-
machine control D6K ECM and
bleshooting code from the beginning.
verify 3196-04 is not active.
Code 3196-04 Not Active - Trouble-
shooting complete.
Test Step 3. Test K953-GY Blade
Angle Right Return Circuit for
Short to Other Circuits in Platform
Wiring Harness.
1. Disconnect platform wiring har-
ness connector PL-C2 (WP 0018,
Figure 215) from equipment ECM
(WP 0148).
2. Disconnect platform wiring har-
ness connector PL-C5 (WP 0018,
Figure 218) from ECM J2: with
Ripper (WP 0147); with Winch
(WP 0149).
3. Disconnect platform wiring har-
ness connector PL-C4 (WP 0018,
Figure 217) from ECM J1: with
Ripper (WP 0147); with Winch
(WP 0149).