Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.
Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.

Field Maintenance Manual 1 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  1113    1114    1115    1116    1117  1118  1119    1120    1121    1122    1123  
img
. . . . . . . . . .
TM 5-2410-240-23-1
0023
Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.
0023
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
3196-04 Blade Angle Right
7. Using digital multimeter (WP
No Continuity on Test Point -
Solenoid Voltage Below Nor-
0283), test for continuity between
Replace equipment ECM (WP 0148).
mal - Continued
PL-C2 terminal 51 (WP 0018, Fig-
Connect platform wiring harness con-
ure 215) and ground.
nector PL-C5 (WP 0018, Figure 218)
on ECM J2: with Ripper (WP 0147);
with Winch (WP 0149).
Connect platform wiring harness con-
nector PL-C4 (WP 0018, Figure 217)
on ECM J1: with Ripper (WP 0147);
with Winch (WP 0149).
Connect platform wiring harness con-
nector PL-C18 (WP 0018, Figure 226)
on chassis wiring harness connector
CH-C1 (WP 0018, Figure 81) with
Ripper (WP 0150); with Winch (WP
0155).
Connect chassis wiring harness con-
nector CH-C22 on blade angle right
solenoid: with Ripper (WP 0018, Fig-
ure 95); with Winch (WP 0018, Figure
266).
For D6K Dozer with Ripper, install
rear plates on machine (WP 0196).
For D6K Dozer with Winch, install rear
bottom guards on machine (WP
0156).
Proceed to step 8.
Continuity on Test Point - Replace
platform wiring harness: with Ripper
(WP 0150); with Winch (WP 0155).
Connect chassis wiring harness con-
nector CH-C22 on blade angle right
solenoid: with Ripper (WP 0018, Fig-
ure 95); with Winch (WP 0018, Figure
266).
For D6K Dozer with Ripper, install
rear plates on machine (WP 0196).
For D6K Dozer with Winch, install rear
bottom guards on machine (WP
0156).
Proceed to step 8.
8. Using MSD (WP 0016), select
Code 3196-04 Active - Repeat trou-
machine control D6K ECM and
bleshooting code from the beginning.
verify 3196-04 is not active.
Code 3196-04 Not Active - Trouble-
shooting complete.
0023-156