Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.
Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.

Field Maintenance Manual 1 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  1116    1117    1118    1119    1120  1121  1122    1123    1124    1125    1126  
img
. . . . . .
TM 5-2410-240-23-1
0023
Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.
0023
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
1934-05 Blade Angle Right
7. Check for active code 1934-05 or
Code 1934-05 Remains Active - Pro-
Solenoid Current Below Nor-
1934-06 in machine control D6K
ceed to Test Step 3.
mal - Continued
ECM (WP 0016).
Code 1934-05 Becomes Inactive
and 1934-06 Becomes Active - Turn
ignition switch and battery disconnect
switch to OFF position (TM 5-2410-
240-10).
Remove jumper wire from PL-C18 ter-
minal 3 and terminal 8 (WP 0018, Fig-
ure 226).
Replace fuel tank and chassis wiring
harness: with Ripper (WP 0153); with
Winch (WP 0154).
Proceed to step 8.
8. Using MSD (WP 0016), select
Code 1934-05 Active - Repeat trou-
machine control D6K ECM and
bleshooting code from the beginning.
verify 1934-05 is not active.
Code 1934-05 Not Active - Trouble-
shooting complete.
Test Step 3. Test 752-YL Blade
Angle Right Solenoid Circuit for
High Resistance or Open in Plat-
form Wiring Harness.
1. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-2410-240-10).
2. Remove jumper wire from PL-C18
terminal 3 and terminal 8 (WP
0018, Figure 226).
3. Disconnect platform wiring har-
ness connector PL-C2 (WP 0018,
Figure 215) from equipment ECM
(WP 0148).