TM 5-2410-240-23-1
0023
Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.
0023
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
3188-04 Auxiliary Valve #1
Test Step 2. Test J922-GY Raise
Below Normal - Continued
Other Circuits in Chassis Wiring
Harness.
1. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-2410-240-10).
2. Disconnect chassis wiring har-
ness connector CH-C2 from auxil-
iary valve #1 port B solenoid.
3. Connect chassis wiring harness
connector CH-C3 on auxiliary
valve #1 port B solenoid (WP
4. Remove right rear access cover
from machine (WP 0191).
5. Disconnect platform wiring har-
ness connector PL-C18 (WP
0018, Figure 226) from chassis
wiring harness connector CH-C1
(WP 0150); with Winch (WP
0155).
No Continuity on Any Test Points -
0283), test for continuity between
Proceed to step 7.
CH-C1 terminal 13 and all other
Continuity on One or More Test
Points - Replace chassis wiring har-
ure 81).
ness: with Ripper (WP 0153); with
Winch (WP 0154).
Proceed to step 8.
0283), test for continuity between
ceed to Test Step 3.
CH-C1 terminal 13 and (WP
0018, Figure 81) and ground.
chassis wiring harness: with Ripper
(WP 0153); with Winch (WP 0154).
Proceed to step 8.
Code 3188-04 Active - Repeat trou-
machine control D6K ECM and
bleshooting code from the beginning.
verify 3188-04 is not active.
Code 3188-04 Not Active - Trouble-
shooting complete.
0023-191