CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
3188-04 Auxiliary Valve #1
Test Step 3. Test J922-GY Raise
Port A Solenoid Voltage
Solenoid Return Circuit for Short to
Below Normal - Continued
Other Circuits in Platform Wiring
Harness.
1. Disconnect platform wiring har-
ness connector PL-C2 (WP 0018,
Figure 215) from equipment ECM
(WP 0148).
2. Disconnect platform wiring har-
ness connector PL-C5 (WP 0018,
Figure 218) from ECM J2: with
Ripper (WP 0147); with Winch
(WP 0149).
3. Disconnect platform wiring har-
ness connector PL-C4 (WP 0018,
Figure 217) from ECM J1: with
Ripper (WP 0147); with Winch
(WP 0149).
4. Using digital multimeter (WP
No Continuity on Any Test Points -
0283), test for continuity between
Proceed to step 5.
PL-C2 terminal 41 and all other
Continuity on One or More Test
circuits in PL-C2 (WP 0018, Fig-
Points - Replace platform wiring har-
ure 215).
ness: with Ripper (WP 0150); with
Winch (WP 0155).
Connect chassis wiring harness con-
nector CH-C2 on auxiliary valve #1
port A solenoid (WP 0018, Figure 82).
For D6K Dozer with Ripper, install
rear plates on machine (WP 0196).
For D6K Dozer with Winch, install rear
bottom guards on machine (WP
0156).
Proceed to step 8.