Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.
Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.

Field Maintenance Manual 1 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  1185    1186    1187    1188    1189  1190  1191    1192    1193    1194    1195  
img
. . . . . . . . . . . .
TM 5-2410-240-23-1
0023
Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.
0023
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
2440-03 Winch Brake Sole-
4. Disconnect platform wiring har-
noid Voltage Above Normal -
ness connector PL-C2 (WP 0018,
Continued
Figure 215) from equipment ECM
(WP 0148).
5. Using digital multimeter (WP
No Continuity on Any Test Points -
0283), test for continuity between
Proceed to step 6.
PL-C5 terminal 5 and all other cir-
Continuity on One or More Test
cuits in PL-C5 (WP 0018, Figure
Points - Replace platform wiring har-
218).
ness (WP 0155).
Connect winch wiring harness con-
nector WF-C1 (WP 0018, Figure 253)
on winch solenoid wiring harness con-
nector WC-C3 (WP 0018, Figure 250)
(WP 0137).
Install rear bottom guards on machine
(WP 0156).
Proceed to step 8.
6. Using digital multimeter (WP
No Continuity on Any Test Points -
0283), test for continuity between
Proceed to step 7.
PL-C5 terminal 5 (WP 0018, Fig-
Continuity on One or More Test
ure 218) and all circuits in PL-C4
Points - Replace platform wiring har-
(WP 0018, Figure 217).
ness (WP 0155).
Connect winch wiring harness con-
nector WF-C1 (WP 0018, Figure 253)
on winch solenoid wiring harness con-
nector WC-C3 (WP 0018, Figure 250)
(WP 0137).
Install rear bottom guards on machine
(WP 0156).
Proceed to step 8.
7. Using digital multimeter (WP
No Continuity on Any Test Points -
0283), test for continuity between
Proceed to Test Step 4.
PL-C5 terminal 5 (WP 0018, Fig-
Continuity on One or More Test
ure 218) and all circuit in PL-C2
Points - Replace platform wiring har-
(WP 0018, Figure 215).
ness (WP 0155).
Connect winch wiring harness con-
nector WF-C1 (WP 0018, Figure 253)
on winch solenoid wiring harness con-
nector WC-C3 (WP 0018, Figure 250)
(WP 0137).
Install rear bottom guards on machine
(WP 0156).
Proceed to step 8.
0023-228