Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.
0023
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
2482-04 Winch Drive Away
7. Using digital multimeter (WP
No Continuity on Any Test Points -
Solenoid Voltage Below Nor-
0283), test for continuity between
Proceed to step 8.
mal - Continued
WC-C2 terminal 3 and all other
Continuity on One or More Test
circuits in WC-C2 (WP 0018, Fig-
Points - Replace winch solenoid wir-
ure 249).
ing harness (WP 0137).
Proceed to step 9.
8. Using digital multimeter (WP
No Continuity on Test Point - Pro-
0283), test for continuity between
ceed to Test Step 2.
WC-C2 terminal 3 (WP 0018, Fig-
Continuity on Test Point - Replace
ure 249) and ground.
winch solenoid wiring harness (WP
0137).
Proceed to step 9.
9. Using MSD (WP 0016), select
Code 2482-04 Active - Repeat trou-
machine control D6K ECM and
bleshooting code from the beginning.
verify 2482-04 is not active.
Code 2482-04 Not Active - Trouble-
shooting complete.
Test Step 2. Test J813-BK Drive-
Away Solenoid Return Circuit for
Short to Other Circuits in Platform
Wiring Harness.
1. Disconnect platform wiring har-
ness connector PL-C2 (WP 0018,
Figure 215) from equipment ECM
(WP 0148).
2. Disconnect platform wiring har-
ness connector PL-C5 (WP 0018,
Figure 218) from ECM J2 (WP
0149).
3. Disconnect platform wiring har-
ness connector PL-C4 (WP 0018,
Figure 217) from ECM J1 (WP
0149).
0023-267