TM 5-2410-240-23-1
0023
Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.
0023
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
2482-03 Winch Drive Away
Code 2482-03 Active - Repeat trou-
Solenoid Voltage Above Nor-
machine control D6K ECM and
bleshooting code from the beginning.
mal - Continued
verify 2482-03 is not active.
Code 2482-03 Not Active - Trouble-
shooting complete.
Test Step 4. Test U717-OR Drive-
Away Solenoid Supply Circuit for
Short to Other Voltage Source in
Platform Wiring Harness.
1. Turn battery disconnect switch
and ignition switch to ON position
(TM 5-2410-240-10).
Voltage Greater Than 0.3 Volts -
0283), measure for voltage
Replace platform wiring harness (WP
between PL-C2 terminal 58 (WP
0155).
0018, Figure 215) and ground.
Connect winch wiring harness con-
(WP 0137).
Install rear bottom guards on machine
(WP 0156).
Proceed to step 3.
Voltage 0.3 Volts or Less - Replace
equipment ECM (WP 0148).
Connect platform wiring harness con-
on ECM J2 (WP 0149).
Connect platform wiring harness con-
on ECM J1 (WP 0149).
Figure 249) on platform wiring har-
Figure 233) (WP 0137).
Install right rear access cover on
machine (WP 0191).
Connect winch wiring harness con-
(WP 0137).
Install rear bottom guards on machine
(WP 0156).
Proceed to step 3.
0023-265