CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
2441-08 Winch Motor Pres-
3. Using digital multimeter (WP
Resistance Less Than 0.3 Ohms -
sure Sensor Abnormal Fre-
0283), measure resistance
Replace machine ECM (WP 0149).
quency, Pulse Width Or
between PL-C5 terminal 50 (WP
Connect winch solenoid wiring har-
Period - Continued
0018, Figure 218) and PL-C33
ness connector WC-C2 (WP 0018,
terminal 8 (WP 0018, Figure 233).
Figure 249) on platform wiring har-
ness connector PL-C33 (WP 0018,
Figure 233) (WP 0137).
Install right rear access cover on
machine (WP 0191).
Connect winch solenoid wiring har-
ness connector WC-C4 on winch oil
pressure sensor (WP 0018, Figure
251) (WP 0136).
Install rear bottom guards on machine
(WP 0156).
Proceed to step 4.
Resistance 0.3 Ohms or Greater -
Replace platform wiring harness (WP
0155).
Connect winch solenoid wiring har-
ness connector WC-C4 on winch oil
pressure sensor (WP 0018, Figure
251) (WP 0136).
Install rear bottom guards on machine
(WP 0156).
Proceed to step 4.
4. Using MSD (WP 0016), select
Code 2441-08 Active - Repeat trou-
machine control D6K ECM and
bleshooting code from the beginning.
verify 2441-08 is not active.
Code 2441-08 Not Active - Trouble-
shooting complete.