TM 5-2410-240-23-1
0023
Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.
0023
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
2482-03 Winch Drive Away
Test Step 2. Test for Shorted Winch
Solenoid Voltage Above Nor- Solenoid Wiring Harness.
mal - Continued
1. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-2410-240-10).
2. Remove right rear access cover
from machine (WP 0191).
3. Disconnect winch solenoid wiring
harness connector WC-C2 (WP
0018, Figure 249) from platform
wiring harness connector PL-C33
0137).
4. Turn battery disconnect switch
and ignition switch to ON position
(TM 5-2410-240-10).
Code 2482-03 Remains Active - Pro-
5. Check for active code 2482-03 in
ceed to Test Step 3.
machine control D6K ECM (WP
Code 2482-03 Becomes Inactive -
ness (WP 0137).
Proceed to step 6.
Code 2482-03 Active - Repeat trou-
machine control D6K ECM and
bleshooting code from the beginning.
verify 2482-03 is not active.
Code 2482-03 Not Active - Trouble-
shooting complete.
Test Step 3. Test U717-OR Drive-
Short to Other Circuits in Platform
Wiring Harness.
1. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-2410-240-10).
2. Disconnect platform wiring har-
Figure 215) from equipment ECM
(WP 0148).
3. Disconnect platform wiring har-
Figure 218) from ECM J2 (WP
0149).
0023-263