• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.
Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.

Field Maintenance Manual 1 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  1233    1234    1235    1236    1237  1238  1239    1240    1241    1242    1243  
img
. . . . . . . . . . . .
TM 5-2410-240-23-1
0023
Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.
0023
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
2482-05 Winch Drive Away
Test Step 5. Test U717-OR Drive-
Solenoid Current Below Nor- Away Solenoid Supply Circuit for
mal - Continued
High Resistance or Open in WInch
Wiring Harness.
1. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-2410-240-10).
2. Remove jumper wire from WC-C3
terminal 3 and terminal 4 (WP
0018, Figure 250).
3. Remove winch from machine (WP
0265).
4. Disconnect winch wiring harness
connector WF-C3 (WP 0018, Fig-
ure 255) from drive-away solenoid
(WP 0018, Figure 258) (WP
0266).
5. Using digital multimeter (WP
Resistance Less Than 5.0 Ohms -
0283), measure resistance
Proceed to Test Step 6.
between WF-C3 terminal 1 (WP
Resistance 5.0 Ohms or Greater -
0018, Figure 254) and WF-C1 ter-
Replace winch wiring harness (WP
minal 3 (WP 0018, Figure 253).
0265).
Proceed to step 6.
6. Using MSD (WP 0016), select
Code 2482-05 Active - Repeat trou-
machine control D6K ECM and
bleshooting code from the beginning.
verify 2482-05 is not active.
Code 2482-05 Not Active - Trouble-
shooting complete.
Test Step 6. Test J813-BK Drive-
Away Solenoid Return Circuit for
High Resistance or Open in Winch
Wiring Harness.
1. Using digital multimeter (WP
Resistance Less Than 5.0 Ohms -
0283), measure resistance
Replace drive-away solenoid (WP
between WF-C3 terminal 2 (WP
0266).
0018, Figure 254) and WF-C1 ter-
Proceed to step 2.
minal 4 (WP 0018, Figure 253).
Resistance 5.0 Ohms or Greater -
Replace winch wiring harness (WP
0265).
Proceed to step 2.
2. Using MSD (WP 0016), select
Code 2482-05 Active - Repeat trou-
machine control D6K ECM and
bleshooting code from the beginning.
verify 2482-05 is not active.
Code 2482-05 Not Active - Trouble-
shooting complete.
0023-276