TM 5-2410-240-23-2
0037
Table 1. Preventive Maintenance Checks and Services (PMCS) - Continued.
LOCATION
ITEM TO BE
MAN- CHECKED OR
ITEM
EQUIPMENT NOT
SERVICED
NO.
INTERVAL
HOURS
PROCEDURE
READY/AVAILABLE IF:
1
50 Hours or
0.5
Recirculation
WARN I N G
Weekly
Cabin Air
Filter
Element
If CBRN exposure is suspected, personnel wearing pro-
tective equipment must handle all air cleaner media.
Contaminated filters must be handled using adequate
precautions and must be disposed of by trained person-
nel. Consult your CBRN Officer or CBRN NCO for appro-
priate handling or disposal procedures. Failure to follow
this warning may cause injury or death to personnel.
Inspect filter element for dirt, debris, Filter dirty, damaged or
missing.
tears, holes, damaged pleats,
gaskets, or seals (WP 0252).
2
250 Hours
1.0
WARN I N G
Final Drive
or Monthly
Oil Level
Check
Oil should be warm to ensure it drains completely from
final drive assembly. Use caution to protect against burns
when draining oil.
Contact with oil can damage skin. Wear gloves when
handling engine oil. If oil contacts skin, wash it off imme-
diately.
Lubricating oil is very slippery. Immediately wipe up any
spills.
Failure to follow these warnings may cause injury or
death to personnel.
N OT E
This procedure is for the left side final drive. Repeat this
procedure for the right side final drive.
0037-3