TM 5-2410-240-23-2
0037
Table 1. Preventive Maintenance Checks and Services (PMCS) - Continued.
LOCATION
ITEM TO BE
MAN- CHECKED OR
ITEM
EQUIPMENT NOT
SERVICED
NO.
INTERVAL
HOURS
PROCEDURE
READY/AVAILABLE IF:
a. Park machine on level ground
Oil level low.
2
250 Hours
1.0
Final Drive
(Cont.) or Monthly
with final drive in drain position
Oil Level
(Figure 1, Item 2).
Check
b. Clean area around final drive
and remove plug (Figure 1, Item 1)
from machine.
c. Fill final drive with oil until oil
reaches bottom of threaded orifice.
d. Install plug (Figure 1, Item 1) on
11 lb-ft (180 15 Nm).
Figure 1.
Final Drive.
0037