OIL FILLER ASSEMBLY REPLACEMENT - Continued
Figure 2. Drive Belt Replacement.

Field Maintenance Manual 2 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  436    437    438    439    440  441  442    443    444    445    446  
img
. .
6
TM 5-2410-240-23-2
0090
FIELD MAINTENANCE
-
DRIVE BELT AND TENSIONER REPLACEMENT
0090
Drive Belt Removal, Drive Belt Tensioner Removal, Cleaning and Inspection, Drive Belt Tensioner
Installation, Drive Belt Installation
INITIAL SETUP
Equipment Conditions
Tools and Special Tools
0
0
Tool Kit, General Mechanic's
Machine parked (TM 5-2410-240-10)
0
(WP 0289, Item 51)
0
Drawings Required
0
Materials/Parts
TM 5-2410-240-24P, Figure 30
0
0
Rag, wiping (WP 0290, Item 21)
0
Estimated Time to Complete
0
References
0.3 Hr
0
0
WP 0282
0
DRIVE BELT REMOVAL
00090
1. Remove four bolts (Figure 1, Item 1), washers (Figure 1, Item 2), and door (Figure 1, Item 3) from machine
(Figure 1, Item 4).
Figure 1. Right Door.
0090
0090-1