TM 5-2410-240-23-2
0160
DRAINING CONTINUED
N OT E
Use a one-inch fitting to depress safety valve on hydraulic tank in order to drain hydraulic
fluid.
Refer to local procedures and plans for storage and disposal of drained fluids.
3. Insert a one-inch fitting (Figure 3, Item 2) and hose (Figure 3, Item 3) on hydraulic tank drain opening
(Figure 3, Item 1).
4. Allow oil to drain into a suitable container.
5. Remove fitting (Figure 3, Item 2) and hose (Figure 3, Item 3) from hydraulic tank drain opening (Figure 3,
Item 1).
Figure 3. Drain Hose and Fitting.
0160
END OF TASK
CLEANING AND INSPECTION
000160
Clean and inspect all parts IAW Mechanical General Maintenance Instructions (WP 0282).
END OF TASK