Figure 2. Drain Plug.
Figure 4. Drain Plug.

Field Maintenance Manual 2 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  1143    1144    1145    1146    1147  1148  1149    1150    1151    1152    1153  
img
.
TM 5-2410-240-23-2
0160
DRAINING CONTINUED
N OT E
Use a one-inch fitting to depress safety valve on hydraulic tank in order to drain hydraulic
fluid.
Refer to local procedures and plans for storage and disposal of drained fluids.
3. Insert a one-inch fitting (Figure 3, Item 2) and hose (Figure 3, Item 3) on hydraulic tank drain opening
(Figure 3, Item 1).
4. Allow oil to drain into a suitable container.
5. Remove fitting (Figure 3, Item 2) and hose (Figure 3, Item 3) from hydraulic tank drain opening (Figure 3,
Item 1).
Figure 3. Drain Hose and Fitting.
0160
END OF TASK
CLEANING AND INSPECTION
000160
Clean and inspect all parts IAW Mechanical General Maintenance Instructions (WP 0282).
END OF TASK
0160-4