Figure 8. Strip Connection to Circuit Breaker.
Figure 10. Cable Connection Inside Panel.

Field Maintenance Manual 3 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  262    263    264    265    266  267  268    269    270    271    272  
img
.
TM 5-2410-240-23-3
0200
INSTALLATION CONTINUED
N OT E
Note position and routing of cable to aid installation.
3. Install circuit breakers (Figure 9, Item 4) in circuit box (Figure 9, Item 5).
4. Install cable (Figure 9, Item 2) and cap (Figure 9, Item 1) on circuit box (Figure 9, Item 5).
5. Install four screws (Figure 9, Item 3) on circuit box (Figure 9, Item 5).
Figure 9. Circuit Breaker Mounting.
0200
0200-7