Figure 1. Fuel Shutoff Valve.
Figure 3. Arctic Kit Heater Fuel Supply Hose and Shutoff Valve.

Field Maintenance Manual 3 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  1126    1127    1128    1129    1130  1131  1132    1133    1134    1135    1136  
img
.
TM 5-2410-240-23-3
0280
REMOVAL CONTINUED
N OT E
Tag hoses to aid installation.
2. Remove clamp (Figure 2, Item 6) and disconnect fuel hose (Figure 2, Item 7) from supply side of fuel metering
pump (Figure 2, Item 5).
3. Remove clamp (Figure 2, Item 9) and fuel hose (Figure 2, Item 10) from outlet side of fuel metering pump
(Figure 2, Item 5).
4. Remove tiedown strap (Figure 2, Item 11) from fuel hose (Figure 2, Item 10). Discard tiedown strap.
5. Remove clamp (Figure 2, Item 9) and fuel hose (Figure 2, Item 10) from arctic kit heater (Figure 2, Item 12).
6. Remove fuel hose (Figure 2, Item 10) from machine.
7. Remove bolt (Figure 2, Item 1), nut (Figure 2, Item 2), washer (Figure 2, Item 3), rubber isolated bracket
(Figure 2, Item 4), and fuel metering pump (Figure 2, Item 5) from mounting bracket (Figure 2, Item 8).
Figure 2. Fuel Metering Pump.
0280
0280-3