Figure 6. Arctic Kit Heater Fuel Supply Hose and Shutoff Valve.
Figure 8. Fuel Shutoff Valve.

Field Maintenance Manual 3 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  1131    1132    1133    1134    1135  1136  1137    1138    1139    1140    1141  
img
.
TM 5-2410-240-23-3
0280
INSTALLATION CONTINUED
N OT E
Position fuel metering pump with output side pointing upward, mounted at an angle
between 15 degrees to 35 degrees (from horizontal).
Install hoses as tagged during removal.
13. Install fuel metering pump (Figure 7, Item 5), rubber isolated bracket (Figure 7, Item 4), washer
(Figure 7, Item 3), bolt (Figure 7, Item 1), and nut (Figure 7, Item 2) on mounting bracket (Figure 7, Item 8).
14. Install fuel hose (Figure 7, Item 10) and clamp (Figure 7, Item 9) on outlet side of fuel metering pump
(Figure 7, Item 5).
15. Install fuel hose (Figure 7, Item 10) and clamp (Figure 7, Item 9) on arctic kit heater (Figure 7, Item 12).
16. Secure fuel hose (Figure 7, Item 10) with new tiedown strap (Figure 7, Item 11)
17. Install fuel hose (Figure 7, Item 7) and clamp (Figure 7, Item 6) on supply side of fuel metering pump (Figure 7,
Item 5).
Figure 7. Fuel Metering Pump.
0280
0280-8