MULTIMETER USAGE
CIRCUIT BREAKER INSPECTION AND TESTING

Field Maintenance Manual 3 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  1163    1164    1165    1166    1167  1168  1169    1170    1171    1172    1173  
img
TM 5-2410-240-23-3
0283
MULTIMETER USAGE CONTINUED
3. Measuring DC Voltage.
a. Select VOLTS DC.
b. Select highest VOLTAGE range or a range that is higher than volts to be measured.
c.
Connect red probe to positive (+) pin and black probe to negative (-) pin.
d. Observe readout as DC voltage in circuit being tested.
4. Measuring Frequency/Duty Cycle.
a. Select applicable VOLTS AC or DC.
b. Press the hertz/percent button once for hertz and twice for duty cycle.
c.
Connect red probe to circuit being tested and black probe to low reference circuit, ground circuit, or
machine ground.
d. Observe readout; values are represented in percent.
END OF TASK
RELAY INSPECTION AND TESTING
000283
1. Inspecting Relays.
a. Check for bent or damaged pins.
b. Check for burned or damaged relay case.
2. Testing Relays.
N OT E
When testing relays, always refer to the circuit diagram printed or stamped on relay case.
A 9V battery also may be used to actuate relay.
a. Using a multimeter, check for continuity across relay coil.
b. Using a multimeter, check that normally open contacts are open and normally closed contacts are shorted
within relay.
END OF TASK