TM 5-2410-241-10
0005
OPERATIONAL INFORMATION CONTINUED
Engine Starting and Machine Warm-Up Continued
0005
WARN I N G
Hearing protection is required when standing within 20 ft (6 m) of the machine while it is
operating. Failure to wear hearing protection may result in hearing loss.
1. Check to make sure all bystanders are clear of machine and briefly sound horn before starting engine.
2. Ensure left joystick is in NO STEER position and parking brake is engaged (WP 0004).
3. Ensure transmission direction selector (left joystick twist handle) is in NEUTRAL position (WP 0004).
WARN I N G
The monitoring system will perform an automatic self-diagnostic functional test whenever
engine start switch is turned to the ON position. If action alarm does not sound or
monitoring displays are not functioning, do not start engine. Notify Field Maintenance.
Failure to follow this warning may result in injury or death to personnel, as any Warning
Category 3 notifications will not be relayed to the operator.
N OT E
The automatic self-diagnostic functional test verifies that all outputs (gauges, alert
indicators, and alarms) are operating correctly.
Alert and status indicatos in upper and lower panels must illuminate briefly.
r
Action lamp must illuminate briefly.
Auxiliary action lamp must illuminate briefly.
Gauges must sweep to vertical, then left, right,and finally settle at current actual value.
Upper digital display window must show readouts in the following sequence:
(a) "888888888888"
(b) "0 RPM P"
Lower digital display window must show readouts in the following sequence;
(a) "Deg C", "kPa", "miles", "kilometers", "rpm", and "liters"
(b) "X 10"
(c) Hourglass symbol for service meter
(d) "888.8.8.8"
(e) Current service meter value
0005-3