TM 5-2410-241-10
0005
OPERATIONAL INFORMATION CONTINUED
Engine Starting and Machine Warm-Up Continued
0005
Figure 1. Gauges and Digital Display Windows.
0005
N OT E
Monitoring system self-diagnostic functional test takes approximately 10 seconds to
complete.
4. Turn engine start switch to ON position, but do not start engine. Allow monitoring system to perform self-
diagnostic functional test.
C AU T I O N
Do not crank engine for more than 30 seconds. Allow starting motor to cool for two
minutes before cranking again or damage to starting motor or batteries may result.
Shut down engine if engine oil pressure does not register on gauge or if engine oil
pressure indicator remains lit 10 seconds after start up.
Failure to follow this cauton may result in engine damage.
i
5. Turn and hold engine start switch to START. Release engine start switch when engine starts.
6. Allow engine to warm up at low idle for five minutes.
7. Slowly operate hydraulics (blade and implements) to allow warm hydraulic oil to circulate through all hydraulic
8. Begin machine operation only after engine coolant temperature gauge begins to move.