Table 1. Preventive Maintenance Checks and Services (PMCS) - Continued
Table 1. Preventive Maintenance Checks and Services (PMCS) - Continued

Operators Manual D7R Dozer Type I With Winch and Type II With Ripper
Page Navigation
  132    133    134    135    136  137  138    139    140    141    142  
img
. .
TM 5-2410-241-10
0012
Table 1. Preventive Maintenance Checks and Services (PMCS) - Continued.
0012
LOCATION
ITEM TO
CHECK/
NOT FULLY MISSION
ITEM
MAN-
SERVICE
PROCEDURE
CAPABLE IF:
NO.
INTERVAL HOURS
47  After
Ether Cylinder
(Cont.)
Figure 14. Ether Cylinder.
0012
48
After
Engine
WARN I N G
Primary Air
Filter
If CBRN exposure is suspected, personnel wearing protec-
tive equipment must handle all air cleaner media. Contami-
nated filters must be handled using adequate precaution
and must be disposed of by trained personnel. Consult
your CBRN Officer or CBRN NCO for appropriate handling
or disposal procedures. Failure to follow this warning may
result in injury or death to personnel.
Inspect engine primary air filter ele- Engine primary air filter ele-
ment. Refer to WP 0014.
ment missing, damaged, or
plugged with dirt.
0012-24