Table 1. Preventive Maintenance Checks and Services (PMCS) - Continued
Figure 18. Cab Recirculation Filter.

Operators Manual D7R Dozer Type I With Winch and Type II With Ripper
Page Navigation
  136    137    138    139    140  141  142    143    144    145    146  
img
TM 5-2410-241-10
0012
Table 1. Preventive Maintenance Checks and Services (PMCS) - Continued.
0012
LOCATION
ITEM TO
CHECK/
NOT FULLY MISSION
ITEM
MAN-
SERVICE
PROCEDURE
CAPABLE IF:
NO.
INTERVAL HOURS
52
After
Cab Recircula-
WARN I N G
tion Filter
If CBRN exposure is suspected, personnel wearing protec-
tive equipment must handle all air cleaner media. Contami-
nated filters must be handled using adequate precaution
and must be disposed of by trained personnel. Consult
your CBRN Officer or CBRN NCO for appropriate handling
or disposal procedures. Failure to follow this warning may
result in injury or death to personnel.
C AU T I O N
Do not use compressed air at pressure greater than 30 psi
(207 kPa) to clean or dry filter element. Failure to follow this
caution may result in damage to filter element.
Filter element must be completely dry before installation.
Failure to follow this caution may result in damage to
equipment.
Filter damaged or missing if
a. Open left cab door.
necessary for mission.
b. Remove two knobs and
recirculation filter.
c. Using a shop light, inspect filter.
d. Clean filter using a maximum of
30 psi (207 kPa) compressed air.
e. Inspect filter for tears or other
damage.
f. Replace filter if damaged.
g. Install filter and two knobs.
h. Close cab door.
0012-28