Table 1. Preventive Maintenance Checks and Services (PMCS) - Continued
Figure 19. Batteries.

Operators Manual D7R Dozer Type I With Winch and Type II With Ripper
Page Navigation
  139    140    141    142    143  144  145    146    147    148    149  
img
TM 5-2410-241-10
0012
Table 1. Preventive Maintenance Checks and Services (PMCS) - Continued.
0012
LOCATION
ITEM TO
CHECK/
NOT FULLY MISSION
ITEM
MAN-
SERVICE
PROCEDURE
CAPABLE IF:
NO.
INTERVAL HOURS
53  After
Batteries and  a. With assistance, remove arctic
(Cont.)
Battery Cables heater battery box cover, if
equipped.
b. Open battery compartment
cover.
Holddown is loose or dam-
c. Check battery holddowns for
aged.
looseness or damage.
d. Inspect batteries for cracked
Battery cases are cracked or
cases and evidence of leaking.
leaks are evident.
N OT E
Original equipment batteries are maintenance-free and do
not have removable caps.
e. Check for missing, broken, split, Damage is noted.
or frayed battery cables.
f. Check for damaged battery
Damage is noted.
posts.
g. If equipped with non-
maintenance free batteries, check
electrolyte level in each cell. If level
is low, fill with distilled water to
bottom of filler opening. Close
battery compartment cover.
0012-31