Table 1. Powertrain Troubleshooting Procedures - Continued.
Table 1. Powertrain Troubleshooting Procedures - Continued.

Field Maintenance Manual 1 D7R Dozer Type I With Winch and Type II With Ripper
Page Navigation
  652    653    654    655    656  657  658    659    660    661    662  
img
. . . . . . . . . . . . . .
TM 5-2410-241-23-1
0020
Table 1. Powertrain Troubleshooting Procedures - Continued.
0020
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1405-6 Transmission Sole-
17. Using a digital multimeter (WP
1.
If continuity is NOT found, proceed
noid Valve #5 Current
0296), test for continuity between
to step 18.
Above Normal - Contin-
pin 48 on powertrain ECM connec- 2.
If continuity is found, replace
ued
tor X-C2 (WP 0018, Figure 4) and
steering control harness (WP
all other pins in powertrain ECM
0178). Ensure all harness connec-
connector X-C3 (WP 0018,
tors are reconnected. Verify cor-
Figure 3).
rect operation of machine (TM 5-
2410-241-10).
18. Remove rear floor plate (WP
0231).
19. Disconnect platform harness con-
nector MA-C7 (WP 0018, Figure
53) from transmission jumper har-
ness connector MP-C2 (WP 0018,
Figure 54).
20. Using a digital multimeter (WP
1. If continuity is found, proceed to
0296), test for continuity between
step 21.
pin 5 on platform harness connec-
2. If continuity is NOT found, replace
tor to transmission jumper harness
platform harness (WP 0209).
MA-C7 (WP 0018, Figure 53) and
Ensure all harness connectors are
pin 24 on platform harness con-
reconnected. Verify correct opera-
nector MA-C14 (WP 0018,
tion of machine (TM 5-2410-241-
Figure 33).
10).
21. Using a digital multimeter (WP
1. If continuity is found, proceed to
0296), test for continuity between
step 22.
pin 7 on platform harness connec-
2. If continuity is NOT found, replace
tor to transmission jumper harness
platform harness (WP 0209).
MA-C7 (WP 0018, Figure 53) and
Ensure all harness connectors are
pin 31 on platform harness con-
reconnected. Verify correct opera-
nector MA-C14 (WP 0018,
tion of machine (TM 5-2410-241-
Figure 33).
10).
22. Using a digital multimeter (WP
1. If continuity is NOT found, proceed
0296), test for continuity between
to step 23.
pin 24 on platform harness con-
2. If continuity is found, replace plat-
nector MA-C14 (WP 0018,
form harness (WP 0209). Ensure
Figure 33) and all other pins in
all harness connectors are recon-
platform harness connector MA-
nected. Verify correct operation of
C14 (WP 0018, Figure 33)
machine (TM 5-2410-241-10).
23. Disconnect transmission jumper
harness connector MP-C1 (WP
0018, Figure 55) from transmis-
sion harness connector P-C1 (WP
0018, Figure 56).
0020-226