Table 1. Powertrain Troubleshooting Procedures - Continued.
0020
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1405-5 Transmission Sole-
25. Using a digital multimeter (WP
1.
If continuity is found, replace pow-
noid Valve #5 Current
0296), test for continuity between
ertrain ECM (WP 0175). Ensure all
Below Normal - Contin-
pin I on transmission harness con-
harness connectors are recon-
ued
nector P-C1 (WP 0018, Figure 56)
nected. Verify correct operation of
and pin 1 on transmission solenoid
machine (TM 5-2410-241-10).
valve #5 connector P-C5 (WP
2.
If continuity is NOT found, replace
0018, Figure 75).
transmission sensor harness (WP
0173). Ensure all harness connec-
tors are reconnected. Verify cor-
rect operation of machine (TM 5-
2410-241-10).
1405-6 Transmission Sole-
1. Connect MSD (WP 0016), select
1. If active 1405-6 code is present,
noid Valve #5 Current
Powertrain D7 ECM, and check for
proceed to step 2.
Above Normal
Diagnostic Codes (WP 0013).
2. If no active codes are present, the
problem does NOT exist at this
time. Resume normal operation.
2. Turn ignition switch and battery
3.
disconnect switch to OFF position
(TM 5-2410-241-10).
3. Remove four bolts (Figure 77,
Item 2), washers (Figure 77,
Item 3), and guard (Figure 77,
Item 1) from machine.
Figure 77. Guard and Retaining Hardware.
0020