TM 5-2410-241-23-1
0021
Table 2. Chassis Troubleshooting Procedures - Continued.
0021
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
819-2 Display Data Link
Abnormal Update - Con-
0296), test for continuity between
instrument panel harness (WP
tinued
pin 1 on instrument panel harness
0260). Ensure all harness con-
gauge cluster connector E-C9
nectors are reconnected. Verify
correct operation of machine (TM
on dash monitor connector E-C7
5-2410-241-10).
2. If continuity is found proceed to
step 7.
0296), test for continuity between
instrument panel harness (WP
pin 2 on instrument panel harness
0260). Ensure all harness con-
gauge cluster connector E-C9
nectors are reconnected. Verify
correct operation of machine (TM
on dash monitor connector E-C7
5-2410-241-10).
2. If continuity is found, proceed to
step 8.
0296), test for continuity between
instrument panel harness (WP
pin 3 on instrument panel harness
0260). Ensure all harness con-
gauge cluster connector E-C9
nectors are reconnected. Verify
correct operation of machine (TM
on dash monitor connector E-C7
5-2410-241-10).
2. If continuity is found, proceed to
step 9.
0296), test for continuity between
instrument panel harness (WP
pin 4 on instrument panel harness
0260). Ensure all harness con-
gauge cluster connector E-C9
nectors are reconnected. Verify
correct operation of machine (TM
on dash monitor connector E-C7
5-2410-241-10).
2. If continuity is found, proceed to
step 10.
0296), test for continuity between
instrument panel harness (WP
pin 5 on instrument panel harness
0260). Ensure all harness con-
gauge cluster connector E-C9
nectors are reconnected. Verify
correct operation of machine (TM
on dash monitor connector E-C7
5-2410-241-10).
2. If continuity is found, proceed to
step 11.
1.
If continuity is found, replace
0296), test for continuity between
instrument panel harness (WP
pin 15 on dash monitor connector
0260). Ensure all harness con-
nectors are reconnected. Verify
other pins in dash monitor con-
correct operation of machine (TM
5-2410-241-10).
2.
ceed to step 12.
0021-29