Table 2. Chassis Troubleshooting Procedures - Continued.
Table 2. Chassis Troubleshooting Procedures - Continued.

Field Maintenance Manual 1 D7R Dozer Type I With Winch and Type II With Ripper
Page Navigation
  689    690    691    692    693  694  695    696    697    698    699  
img
. . . . . . . . . . .
TM 5-2410-241-23-1
0021
Table 2. Chassis Troubleshooting Procedures - Continued.
0021
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
600-8 Hydraulic Oil Temper-
12. Using digital multimeter (WP
1.
If continuity is NOT found, replace
ature Sensor Voltage
0296), test for continuity between
platform harness (WP 0209) and
Abnormal Signal - Con-
pin 6 on platform harness connec-
instrument panel harness (WP
tinued
tor MA-C17 (WP 0018, Figure 85)
0260). Ensure all harness con-
and pin 10 on dash monitor con-
nectors are reconnected. Verify
nector E-C7 (WP 0018, Figure 5).
correct operation of machine (TM
5-2410-241-10).
2. If continuity is found, proceed to
step 13.
13. Using digital multimeter (WP
1.
If continuity is found, replace plat-
0296), test for continuity between
form harness (WP 0209) and
pin 10 on dash monitor connector
instrument panel harness (WP
E-C7 (WP 0018, Figure 5) and all
0260). Ensure all harness con-
other pins in dash monitor con-
nectors are reconnected. Verify
nector E-C7 (WP 0018, Figure 5).
correct operation of machine (TM
5-2410-241-10).
2. If continuity is NOT found, replace
dash monitor ECM (WP 0262).
Ensure all harness connectors
are reconnected. Verify correct
operation of machine (TM 5-2410-
241-10).
819-2 Display Data Link
1. Connect MSD (WP 0016). Select
1. If active 819-2 code is present,
Abnormal Update
CAT Monitoring System D7R
proceed to step 2.
ECM and check for Diagnostic
2. If no active codes are present,
Codes or Event Codes (WP
problem does NOT exist at this
0013).
time. Resume normal operation.
2. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-2410-241-10).
3. Disconnect dash monitor connec-
tor E-C7 (WP 0018, Figure 5)
from instrument panel (WP 0262).
4. Disconnect instrument panel har-
ness gauge cluster connector E-
C9 (WP 0018, Figure 86) from
gauge cluster (WP 0262).
5. Disconnect instrument panel har-
ness lamp gear module connector
E-C10 (WP 0018, Figure 87) from
lamp gear module (WP 0262).
0021-28